CBBMP - PARABOND C-70

  • MSDS: CBBMP
  • Manufacturer: PARA CHEM SOUTHERN INC
  • Product Name: PARABOND C-70
  • National Stock Number: 7930-00N024195
Product Identification

Product ID:PARABOND C-70
MSDS Date:04/12/1988
FSC:7930
NIIN:00N024195
MSDS Number: CBBMP

Responsible Party
PARA-CHEM SOUTHERN INC
SIMPSONVILLE, SC 29681
US

Emergency Phone: 803-967-7691

Info Phone: 803-967-7691

Preparer: B L EUDY

Cage: 15865

Contractor
PARA-CHEM SOUTHERN INC
127 SIMPSONVILLE, SC 29681 US

Telephone: (803) 967-7691

Cage: 15865

Ingredients

ACETONE (SARA 313) (CERCLA)

CAS: 67-64-1

RTECS: AL3150000

Fraction By Weight: 95%

OSHA PEL 1000 PPM

ACGIH TLV: 750 PPM;1000 STEL

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


2-BUTANONE (MEK) (SARA 313) (CERCLA)

CAS: 78-93-3

RTECS: EL6475000

Fraction By Weight: 5%

OSHA PEL 200 PPM

ACGIH TLV: 200 PPM; 300 STEL

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


800.

RTECS: 9999999VO

OSHA PEL N/K

ACGIH TLV: N/K


ANY TYPE. DO NOT TAKE INTERNALLY. KEEP OUT OF

RTECS: 9999999ZZ


THERE ARE NOT DUST HAZS FROM POWDERS IN IT. WHEN

RTECS: 9999999ZZ


THE USER MUST DETERMINE IF THERE IS A DUST HAZARD

RTECS: 9999999ZZ


AND FULL LENGTH FACESHIELD .

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYE:LIQ CAUSES SEV IRRIT. VAPS CAUSE
SLIGHT TO MOD IRRIT. SKIN:LIQ/VAPS CAUSES MOD IRRIT. INHAL:CAN
CAUSE NOSE & THROAT IRRIT, HDCH, NAUS, DROWS, DIZZ & INCOOR.
INGEST:MOD TOX, MAY CAUSE NAUS, VOMIT, & DIARR. ING 1:SKIN & RESP
SYS. PREPLACEMENT & PERIODIC EXAMS W/CONSIDERATION TO SKIN & RESP
CNDTNS. (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: ACETONE CAN BE DETECTED IN BLOOD,
URINE & EXPIRED AIR. ING 2:SKIN, EYES, LUNGS & CNS. PREPLACEMENT &
PERIODIC EXAMS W/CONSIDERATION TO POINTS OF ATTACK. REPORTS HAVE
ASSOC RPTD & PRLNGD OVER EXP TO SOLVS W/PERM BRAIN & NERV SYS DMG.
INTENTIONAL MISUSE BY DELIB CONC & INHALING CONTENTS MAY BE
HARMFUL/FATAL.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:EYES: FLUSH WITH WATER FOR AT LEAST 15 MINUTES. CALL MD IF
IRRITATION OCCURS. SKIN: WASH WITH SOAP AND WATER. CALL MD IF
IRRITATION OCCURS. INHALATION: MOVE PERSON TO FRESH AIR. IF
BREATHING STOPS, AD MINISTER ARTIFICIAL RESPIRATION AND CALL MD
IMMEDIATELY. INGESTION: TO CONSCIOUS PERSON, GIVE 2 GLASSES OF
WATER. INDUCE VOMITING AND CALL MD IMMEDIATELY.

Fire Fighting

Flash Point Method:TCC
Flash Point:2F,-17C
Lower Limits:1.8%
Upper Limits:12.8%
Extinguishing Media:DRY CHEMICAL, CARBON DIOXIDE, ALCOHOL FOAM.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT.
Unusual Fire/Explosion Hazard:ELIMINATE SOURCES OF IGNITION BECAUSE
VAPORS MAY TRAVEL ALONG GROUND OR BE MOVED BY VENTILATION.

Accidental Release

Spill Release Procedures:VENTILATE, DIKE AND DISPENSE SAND,
SAWDUST/VERMICULITE. COLLECT AND PLACE IN WASTE CONTAINER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE >40F. DO NOT STORE >100F. KEEP
CLOSURE TIGHT & CNTNR UPRIGHT TO PVNT LEAKAGE. STORE DRUM OUT OF
SUN & AWAY FROM HEAT. STORE ONLY IN VENTED AREA.
Other Precautions:RELIEVE INTERNAL PRESS WHEN RECIEIVED & AT LEAST
WEEKLY THEREAFTER BY SLOWLY LOOSENING CLOSURE. RETIGHTEN IMMED. DO
NOT STORE/USE NEAR HEAT, SPARKS/FLAME. DRUMS OF MATL SHOULD BE
GROUNDED & BONDED WH EN POURING. NEVER USE PRESS TO (SUPDAT)

Exposure Controls

Respiratory Protection:IF CONDITIONS EXIST WHERE PEL OR TLV MAY BE
EXCEEDED, WEAR NIOSH/MSHA APPROVED RESPIRATOR.
Ventilation:USE SUFF VENT, IN VOL & PATTERN, TO KEEP AIR CONTAM CONC
BELOW PEL OR TLV.
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS (ING 7)
Other Protective Equipment:EMERGENCY EYEWASH & DELUGE SHOWER MEETING
ANSI DESIGN CRITERIA.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
OTHER PREC:EMPTY. DRUM IS NOT PRESS VESSEL. DO NOT PUNCTURE, DRAG/SLIDE
CNTNR. PVNT PRLGD/RPTD BRTHG OF VAP/SPRAY MIST. CANNOT BE MADE
NONPOISONOUS. AVOID CONTACT W/OR BRTHG OF VAPORS RELEASED DURING
CURING PROCESS. DO NOT WELD/FLAME-CUT AN EMPTY DRUM. DO NOT USE
CHLORINATED SOLVS TO CLEAN ALUMINUM EQUIP OF (ING 4)

Chemical Properties

Boiling Pt:B.P. Text:>133F,>56C
Vapor Pres:157
Vapor Density:2.2
Spec Gravity:0.80(H*2O=1)
Evaporation Rate & Reference:6.1 (BUAC=1)
Solubility in Water:MODERATE
Appearance and Odor:CLEAR LIQUID W/KETONE ODOR.
Percent Volatiles by Volume:100

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:BURNING CAN PRODUCE CO, CO*2, H*20 AND
VAPORS OF CHEMICALS.

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE W/LOCAL, STATE &
FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.